3-5
e. WordPad application selected and SonarSerial.ini open:
Figure 3-8: Edit SonarSerial.ini in WordPad
3. Change the Baud Rate under the COM 5 section. A copy of the file is below.
-------------------------------------------------------------------------------
; Pitch Roll Sensor
[Serial1]
Create=1
Port=3
Baud=19200
Parser=4
;ParserParameters=ANGLE 180
;Look for Mag serial data on the topside Com Port #5
[Serial5]
Create=1
; Magnetometer support: Mini Explorer and SeaSpy II
Port=4
NetworkRaw=1
Baud=9600
;Initialize SeaSpy II to start scrolling
InitString=\r
;Change [Serialn] above for n= 4,5,6, etc to match Topside Physical Com port #
-------------------------------------------------------------------------------