Page #18 background imageLoading...
Page #18 background image
18
ENGLISH
USER CONTROLS (REMOTE CONTROL)
- ON/OFF
- Switch-on/switch-off
- Manual mode setting
Power setting
Fan setting
- Automatic mode setting
Temperature setpoint setting
Fan setting
- RELAX function
- From the Menu page:
• Load Pellets (SCREW LOAD)
• Stand By
• Crono-Program
• Night
Date / time
• Display
• Language
• Beep (BUZZER)
• Info (technician only)
• Technical menu (technician only)
We describe the procedures below.
ON/OFF
hold the ON/OFF button down to turn the product ON.
When ON, the product has a ame (ignition phase,
etc.) when there is a heating demand.
Switch-on/Switch-off
The ON/OFF button switches the product on (starts
the ignition phase) or off (starts the switch off phase)
manually in Manual mode only.
In Automatic mode, the product responds to the
heating demand.
Setting Manual/Automatic
Press the OK button for 2 seconds to switch from
manual to automatic or vice versa.
In Manual mode, the display reads “Man”
In Automatic mode, the temperature displays.
In automatic- Room Temperature Setting
Set Room Temperature (read by the remote control,
this should be be positioned in the room the product
is installed in)
Set the temperature setpoint (Set) with the “+” and “-“
buttons.
In manual- Power setting
Set the power level (displayed by the ame symbol)
with the “+” and “-“ buttons.
The power level displays next to the ame symbol.
Ventilation setting
Follow the instructions below to manually regulate the
power levels of the fan.
Press “OK” once
The fan setting displays, next to the blade symbol
representing the fan.
Set the fan level with the “+” and “-“ buttons.
The blades ll in to indicate the current setting.
Con rm by pressing the OK button for 2 seconds.
The fan setting can also follow the room temperature
demand (reduce when the temperature is close to the
desired temperature or increase vice versa).
To activate this mode, press the + button to above the
maximum fan setting. The letter “A” will appear next to
the blade symbol.
THE NUMBER NEXT TO THE FAN BLADE OR FLAME
ONLY DISPLAYS WHILE THE SETTING IS BEING
MADE.
USER INSTRUCTIONS

Other manuals for EdilKamin SLIDE

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EdilKamin SLIDE and is the answer not in the manual?

EdilKamin SLIDE Specifications

General IconGeneral
TypePellet Stove
Efficiency (min)90%
Tank capacity15 kg
Diameter of smoke outlet80 mm
Heating power (max)9 kW