EasyManua.ls Logo

Edwards Drystar EDP160 Series

Edwards Drystar EDP160 Series
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© Edwards Limited 2011. All rights reserved. Page 49
Edwards and the Edwards logo are trademarks of Edwards Limited.
Maintenance
A705-40-880 Issue B
9. Use the steel rod to turn the pump clockwise through three or four complete revolutions. If the pump seizes,
this is probably because of a hydraulic lock in the pump:
Wait for a few seconds for the cleaning solution to drain through the pump, or
Remove one or more of the purge port blanking plugs (Figure 10, items 4 and 5) to allow the cleaning solution
to drain out of the purge port(s), then refit the plug(s) to the purge port(s).
10.If necessary, repeat Step 5 to 9 to flush the pump again.
11.Remove the blanking-flange from the pump-inlet (Figure 1, item 3) and reconnect the pump-inlet to your
process system (refer to Section 3.10.1) or open the pump-inlet isolation-valve.
12.Reconnect the pump-outlet to your exhaust pipeline: refer to Section 3.10.2.
13.If necessary, recouple the pump-motor to the pump: refer to attached torque limiter amendment.
14.Dispose of the used cleaning solution and deposits removed.