A705-74-880
Issue K Original
Instruction Manual
GV Dry Vacuum Pumps
Description Electrical Supply Item Number
GV260 Dry Vacuum Pump 380 - 415 V, 50 Hz A705-71-900
GV260 Dry Vacuum Pump 230 / 460 V, 60 Hz A705-71-908
GV410 Dry Vacuum Pump 380 - 415 V, 50 Hz A705-73-900
GV410 Dry Vacuum Pump 230 / 460 V, 60 Hz A705-73-908
GV600 Dry Vacuum Pump 380 - 415 V, 50 Hz A705-74-900
GV600 Dry Vacuum Pump 230 / 460 V, 60 Hz A705-74-908
GV600 Bareshaft Dry Vacuum Pump 50 Hz A705-74-985
GV600 Bareshaft Dry Vacuum Pump 60 Hz A705-74-986
GV600F Bareshaft Dry Vacuum Pump 50 Hz A705-75-985
GV600F Bareshaft Dry Vacuum Pump 60 Hz A705-75-986

Table of Contents

Questions and Answers

  • E
    Erik MossAug 12, 2025
    What to do if the seals failed in Edwards DRYSTAR GV?
    • D
      douglas51Aug 12, 2025
      If the seals in your Edwards Water Pump have failed, they must be replaced.
  • K
    kennethblackAug 19, 2025
    Why is my Edwards Water Pump overheating?
    • V
      Victoria RiddleAug 20, 2025
      Several issues can cause the Edwards Water Pump to overheat or have unstable temperatures. The cooling-water flow might be inadequate or interrupted; ensure correct cooling-water flow before restarting the pump. The interstage relief valve could be stuck open or closed, requiring inspection, overhaul, or replacement. A failed shaft-seal purge, low oil level, faulty pump-motor, or failed seals can also cause this issue. Check and adjust the air or nitrogen pressure for the shaft-seals if needed, replenish the oil, or replace the pump-motor or seals if necessary.
  • S
    steven03Aug 27, 2025
    What to do if my Edwards Water Pump suddenly stops?
    • M
      Maurice ScottAug 27, 2025
      If your Edwards Water Pump suddenly stops, several factors could be at play. The shutdown thermal snap-switch might have stopped the pump due to high temperature; ensure sufficient cooling-water flow at the correct pressure and temperature. An interruption or failure in the cooling-water supply can also cause this. Check and clean the cooling jacket. In case of hydraulic lock, isolate electrical supply, isolate pump from process, remove the coupling cover and rotate the pump drive shaft by inserting a bar into the holes in the motor coupling. If the pump has seized due to a faulty switch, contact your supplier or Edwards for advice.
  • H
    Heather MorrisonSep 3, 2025
    How to fix a hydraulic lock in Edwards Water Pump?
    • C
      Charles LewisSep 3, 2025
      To fix a hydraulic lock in your Edwards Water Pump, isolate the electrical supply and the pump from the process. Remove the coupling cover and rotate the pump drive shaft by inserting a bar into the holes in the motor coupling.

Edwards DRYSTAR GV Series Specifications

General IconGeneral
BrandEdwards
ModelDRYSTAR GV Series
CategoryWater Pump
LanguageEnglish