A591-40-880
Issue A Original
Instruction Manual
iXL120 Dry Pump System

Questions and Answers

  • M
    Melinda ChanAug 17, 2025
    What to do if Edwards Water Pump shows warning 1.01 Power interrupt?
    • J
      Justin PaulAug 17, 2025
      If your Edwards Water Pump displays a 'Warning 1.01 Power interrupt', it indicates that the electrical supply to the pump experienced a brownout lasting longer than 1 second. You should check the electrical supply to resolve this issue.
  • G
    Gregory WilliamsAug 19, 2025
    What to do if Edwards iXL120 displays warning 152.01 Valve Not Shut?
    • J
      Jeremy SmallAug 19, 2025
      If the Edwards Water Pump shows a 'Warning 152.01 Valve Not Shut', it means the foreline gate valve hasn't closed properly. Check the wiring and air supply to the gate valve. Keep in mind that this warning will only disappear once the valve has been successfully opened and closed.
  • M
    Mrs. Sherry CarrollAug 22, 2025
    What to do if Edwards iXL120 displays warning 71.13 AC Sup Missing?
    • T
      thendersonAug 22, 2025
      If the Edwards Water Pump displays a 'Warning 71.13 AC Sup Missing', it means the pump controller can't communicate with the accessory module. Verify that the accessory module is correctly connected to the pump, and then cycle the power to the pump.
  • A
    aruizAug 25, 2025
    How to fix Edwards Water Pump warning 55.13 Sensor missing?
    • M
      Molly WilliamsAug 26, 2025
      If your Edwards Water Pump is showing 'Warning 55.13 Sensor missing', the dry pump temperature sensor may be disconnected or faulty. Verify that the sensor is properly fitted and correctly connected.
  • J
    Jimmy JonesAug 27, 2025
    What to do if Edwards iXL120 shows a power interrupt warning?
    • C
      Casey MilesAug 27, 2025
      If your Edwards Water Pump displays a 'Power interrupt' warning, it indicates that the electrical supply to the pump experienced a brownout lasting longer than 1 second. You should check the electrical supply to resolve this issue.
  • J
    Jay MullinsAug 30, 2025
    What to do if Edwards iXL120 Water Pump displays AC Sup Missing warning?
    • Z
      Zachary WolfAug 30, 2025
      If the Edwards Water Pump displays an 'AC Sup Missing' warning, it means the pump controller can't communicate with the accessory module. First, ensure the accessory module is correctly connected to the pump. Then, cycle the power to the pump. If the warning continues, contact Edwards.
  • T
    timothy65Sep 2, 2025
    How to fix Edwards iXL120 Water Pump 'Sensor missing' warning?
    • A
      Allison MorrisonSep 2, 2025
      If you're seeing a 'Sensor missing' warning on your Edwards Water Pump, the dry pump temperature sensor might be disconnected or faulty. Verify that the sensor is properly fitted and correctly connected.
  • P
    Pamela HillSep 5, 2025
    What to do if Edwards iXL120 Water Pump shows 'Valve Not Shut' warning?
    • A
      Adam BondSep 5, 2025
      If your Edwards Water Pump displays a 'Valve Not Shut' warning, it indicates that the foreline gate valve has failed to close. Check the wiring and air supply to the gate valve. Note that this warning will only disappear once the valve has been successfully opened and closed.
  • C
    Cassandra BellSep 7, 2025
    What to do if Edwards Water Pump shows 'Valve Not Open' warning?
    • T
      taylorrobertSep 8, 2025
      If your Edwards Water Pump displays a 'Valve Not Open' warning, it indicates that the foreline gate valve has failed to open. Check the wiring and air supply to the gate valve. Note that this warning will only disappear once the valve has been successfully closed and opened.
  • M
    Matthew PerezSep 10, 2025
    What causes 'No DP Inv Comms' warning on Edwards iXL120, and how to fix it?
    • C
      crosschristinaSep 10, 2025
      The 'No DP Inv Comms' warning on your Edwards Water Pump means the pump controller can't communicate with the dry pump inverter. Check the wiring between the pump controller and the dry pump inverter.

Summary

Introduction to iXL120 Dry Pump System

Scope, Applications, and System Overview

Defines manual's purpose, intended applications, and system components.

Priority of Control

Explains control hierarchy between panel, PDT, and tool.

Technical Data for iXL120

General Specifications and Performance

Covers dimensions, mass, noise, and performance metrics.

Loading and Electrical Data

Details weight distribution and electrical ratings.

Connections, Cooling, and Nitrogen Supply

Covers electrical, cooling water, and nitrogen supply specifications.

Installation Procedures for iXL120

Safety and Preparation

Essential safety guidelines and unpacking instructions.

System Placement and Connections

Procedures for locating, connecting to vacuum/exhaust.

Electrical, Control, and Cooling Integration

Covers electrical supply, controls, EMS, and water connections.

Commissioning the iXL120 System

Steps for initial start-up and system verification.

Operation of the iXL120 System

Start-up, Status, and Shutdown

Guides on system start-up, status indicators, and shutdown procedures.

Alarms, Emergency Stops, and Restarts

Procedures for handling alarms, EMS, and restarting the pump.

Auto Tune Functionality

Explains the Auto Tune process, requirements, configuration, and operation.

Maintenance of the iXL120

Safety and Relocation Procedures

Outlines safety measures, maintenance intervals, and system relocation.

Draining, Inspection, and General Maintenance

Covers draining water, inspecting components, and general upkeep.

Transportation, Storage, and Disposal Guidelines

Transportation, Storage, and Disposal Guidelines

Provides instructions for safely moving, storing, and disposing of the equipment.

Service, Spares, and Accessories

Service and Parts Information

Information on service options and ordering spare parts.

System Accessories Overview

Lists and describes available accessories for the pump.

Appendix A1: Pump Display Terminal (PDT)

PDT Overview, Operation, and Menu Navigation

Introduces the PDT, its functions, and menu navigation.

Appendix A2: Troubleshooting

Warnings and LED Indicators

Covers pump warnings, their causes, and LED indications.

PDT Warnings, Alarms, and Inverter Faults

Details PDT messages, alarms, and inverter fault interpretation.

Other Troubleshooting Topics

Addresses communication issues and other fault conditions.

Edwards iXL120 Specifications

General IconGeneral
BrandEdwards
ModeliXL120
CategoryWater Pump
LanguageEnglish

Related product manuals