This manual provides installation information for the following
Edwards Ironworkers:
25 Ton 40 Ton 50 Ton
55 Ton 60 Ton 65 Ton
75 Ton 100 Ton 100 Ton DX
120 Ton Elite 110 Elite 110/65 D.O.
Environmental Requirements at Work Station
The work station environment for your Edwards Ironworker must meet
the following minimum requirements:
• Floor area: Assure that the machinery work area provides
for a stable, adequately sized and load rated oor area for
material movement to and from the machinery work stations.
• Shelter: Edwards Ironworkers are designed for indoor use
only. Protect your Ironworking machinery from water, salts
and corrosive elements.
• Lighting: 500LUX (50 footcandles) minimum.
• Operating Temperature: This equipment will operate
correctly in its intended ambient, at a minimum between
+5° C and +40°C.
• Relative Humidity: This equipment will operate correctly
within an environment at 50% RH, +40°C. Higher RH may
be allowed at lower temperatures. Measures shall be taken
by the Purchaser to avoid the harmful effects of occasional
condensation.
• Altitude: This equipment will operate correctly up to 1000m
above mean sea level.
• Transportation and Storage: This equipment will withstand,
or has been protected against, transportation and storage
temperatures of -25°C to +55°C and for short periods up to
+70°C. It has been packaged to prevent damage from the
effects of normal humidity, vibration and shock.
Electrical Requirements at Work Station
Locate your Ironworker directly adjacent to your power supply. Con rm
that power supply is not connected in series with other machinery. Pro-
vide dedicated electrical socket and circuit breaker for each Ironworker
installed. Edwards Ironworkers are protected from voltage variations
provided the variation does not exceed +/- 10% machine rating.
Installation Requirements
Electrical Performance Speci cation
Machine Motor # Type Brand 60Hz/V FLA 50Hz/V FLA
25 Ton 116676 1Hp 1~ Leeson 60 Hz 115/208-230 12/6 50 Hz 110/220 13/6
40, 50, 55, 60 Ton, 132089 5Hp 1~ Leeson 60 Hz 230 19 50 Hz 208-220 23-22
Porta-Power 132077 5Hp 3~ Leeson 60 Hz 208-230/460 14/7 50 Hz 190/380 16/8
CEM3615T-5 5Hp 3~ Baldor 60 Hz 575 5
65, 75, 100 Ton, 132089 5Hp 1~ Leeson 60 Hz 230 19 50 Hz 208-220 23-22
Elite 110, 140809 7.5Hp 3~ Leeson 60 Hz 208-230/460 22-21/10 50 Hz 190/380 24/12
Elite 110/65 D.O. CEM3710T-5 7.5Hp 3~ Baldor 60 Hz 575 8
141140 7.5Hp 1~ Leeson 60 Hz 230 36
100DX, 120 Ton CEM3714T 10Hp 3~ Baldor 60 Hz 208-230/460 25-24/12
EM3714T-5 10Hp 3~ Baldor 60 Hz 575 10
CEM3714T-50 10Hp 3~ Baldor 50 Hz 220/380/440 28/16/14
CL3712T 10Hp 1~ Baldor 60 Hz 208-230 38