Edwards SIGA-270 - Specifications and Ordering; Specifications Summary; Ordering Information

Edwards SIGA-270
4 pages
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 4 of 4 DATA SHEET E85001-0279
Not to be used for installation purposes. Issue 1
12-18-17
LIFE SAFETY & INCIDENT MANAGEMENT
Contact us...
Email: edwards.fire@fs.utc.com
Web: edwards-fire.com
1016 Corporate Park Drive
Mebane, NC 27302
EDWARDS is a registered mark in the
United States and other countries.
© 2018 United Technologies Corporation.
All rights reserved.
Specifications
Ordering Information
Catalog Number
SIGA-270, SIGC-
270F, SIGC-270B
SIGA-270P,
SIGC-270PB SIGA-278
Description
Single Action
- One Stage
Single Action -Two
Stage (Presignal)
Double Action
- One Stage
Addressing
Requirements
Uses 1 Module
Address
Uses 2 Module
Addresses
Uses 1 Module
Address
Operating Current
Standby = 250µA
Activated = 400µA
Standby = 396µA
Activated = 680µA
Standby = 250µA
Activated = 400µA
Construction & Finish
Diecast Zinc - Red Epoxy
with aluminum markings
Lexan - Red with
white markings
Type Code
Factory Set
Operating Voltage
15.2 to 19.95 Vdc (19 Vdc nominal)
Storage and Operating
Environment
Operating Temperature: 32ºF to 120ºF (0ºC to 49ºC)
Storage Temperature: -4ºF to 140ºF (-20ºC to 60ºC) Humidity: 0 to 93%
RH
LED Operation
On-board Green LED - Flashes when polled
On-board Red LED - Flashes w hen in alarm
Compatibility
Use With: Signature Loop Controller
Agency Listings
UL, ULC (note 1), MEA, CSFM, FM
Note: SIGC-270F, SIGC-270B and SIGC-270PB are ULC listed only. Suffix “F” indicates French markings.
Suffix “B” indicates English/French biling ual markings.
Catalog
Number Description
Ship Wt.
lbs (kg)
SIGA-270 One Stage Fire Alarm Station, English Markings - UL/ULC Listed
1 (0.5)
SIGC-270F One Stage Fire Alarm Station, French Markings - ULC Listed
SIGC-270B One Stage Fire Alarm Station, French/English Markings - ULC Listed
SIGA-270P
Two Stage (Presignal) Fire Alarm Station, English Markings - UL/ULC
Listed
SIGC-
270PB
Two Stage (Presignal) Fire Alarm Station, French/English Markings
- ULC Listed
SIGA-278
Double Action (One Stage) Fire Alarm Station, English Markings
- UL/ULC Listed
Accessories
32997 GA Key w/Tag - for pre-signal station (CANADA ONLY)
0.1 (.05)
276-K2 GA Key - for pre-signal station (USA ONLY)
276-K1 Station Reset Key, Supplied with all Key Reset Stations
27165 12 Glass Rods - for SIGA-270 series (CANADA ONLY)
270-GLR 20 Glass Rods - for SIGA-270 series (USA ONLY)
276-GLR 20 Glass Rods - for SIGA-278 series
276B-RSB Surface Mount Box, Red - for SIGA pull stations 1 (0.6)