EasyManua.ls Logo

Edwards SIGA-REL Technical User Manual

Edwards SIGA-REL Technical
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SIGA-REL Technical
Reference Manual
P/N 387348-EN • REV 007 • ISS 22SEP17
Question and Answer IconNeed help?

Do you have a question about the Edwards SIGA-REL Technical and is the answer not in the manual?

Edwards SIGA-REL Technical Specifications

General IconGeneral
BrandEdwards
ModelSIGA-REL Technical
CategoryProtection Device
LanguageEnglish

Summary

Chapter 1 Product Design

Introducing the SIGA-REL

Overview of the SIGA-REL Releasing Module and its components.

Fire Suppression Systems

Details on deluge and preaction sprinkler systems, and automatic extinguishing systems.

Compatible Panels and Devices

Lists compatible fire alarm control panels, software, power supplies, and other devices.

Specifications

Technical specifications for power riser, release, prerelease, and abort circuits.

Application Block Diagrams

Illustrates system integration for deluge, preaction, and automatic extinguishing systems.

Release Sequences

Explains automatic and manual release sequence operations and timing.

Chapter 2 Installation

Mounting the SIGA-REL

Instructions for mounting the SIGA-REL in various enclosures like MFC-A cabinets.

Setting Abort Mode and Delay Times

Configuration of abort modes and delay timers using DIP switches for system control.

Reading the LEDs

Explains the meaning and function of the SIGA-REL status LEDs (DS1-DS7).

Wiring the SIGA-REL

Detailed wiring instructions and diagram for connecting the SIGA-REL module.

Warning Notice Placards

Guidance on posting warning placards for safe operation and system service.

Chapter 3 Programming

Programming the SIGA-REL in the 2-SDU

Steps for adding SIGA-REL to the database and configuring it using 2-SDU software.

Programming the SIGA-REL in the 3-SDU

Steps for adding SIGA-REL to the database and configuring it using 3-SDU software.

Programming the SIGA-REL in the QS-CU

Guide for programming the SIGA-REL using the QS-CU software, including system requirements.

Chapter 4 Testing and Troubleshooting

Code Requirements for Testing

Overview of applicable code requirements for fire suppression system testing.

System Testing

Procedures for checking installation, programming, and connecting releasing solenoids.

SIGA-REL Fault Messages on EST2 Panels

Lists and explains SIGA-REL fault messages and LED indications on EST2 panels.

SIGA-REL Fault Messages on EST3 Panels

Lists and explains SIGA-REL fault messages and LED indications on EST3 panels.

SIGA-REL Fault Messages on QuickStart Panels

Lists and explains SIGA-REL fault messages and LED indications on QuickStart panels.