INSTALLATION GUIDE AND OWNER’S MANUAL
LavAdvantage™
ELECTRIC INSTANTANEOUS WATER HEATERS

Questions and Answers

  • L
    Lisa DavidAug 20, 2025
    What to do if my EemaX Water Heater has no heat?
    • N
      Nicole WilliamsAug 20, 2025
      If your EemaX Water Heater isn't producing heat, the cause may be element failure, a tripped or malfunctioning ECO, failed open triac(s), a malfunctioning relay/contactor, control board failure, or an out-of-spec inlet water supply. You can measure element resistance with the unit completely turned off to troubleshoot.
  • B
    Bernard Saunders MDAug 22, 2025
    What to do if EemaX LavAdvantage SPEX3512T has undervoltage?
    • M
      Michael LinAug 22, 2025
      If your EemaX Water Heater is experiencing undervoltage, it indicates that the inlet voltage is too low compared to the heater's specifications. Provide voltage within specified range.
  • D
    Dawn GordonAug 25, 2025
    Why is my EemaX LavAdvantage SPEX3512T producing low heat?
    • C
      chambersjenniferAug 25, 2025
      Low heat from your EemaX Water Heater can stem from undervoltage, failed open triac(s), control board failure, or inlet/outlet thermistor(s) failure. Verify the power supply (voltage) while the heater is running to address this issue.
  • J
    John PerryAug 26, 2025
    What to do if EemaX Water Heater flow is too high?
    • M
      mcculloughstevenAug 27, 2025
      If the flow in your EemaX Water Heater is too high, preventing the water from heating to the setpoint temperature, reduce the flow. You can achieve this by using an outlet flow restrictor or a faucet aerator.
  • J
    Jonathan BerryAug 28, 2025
    What to do if EemaX Water Heater shows freeze warning?
    • M
      Michael McdonaldAug 28, 2025
      If your EemaX Water Heater displays a freeze warning, it means the inlet temperature is too low (below 35°F). To resolve this, increase the temperature of the inlet water to meet product specifications.
  • W
    William NolanAug 30, 2025
    What to do if EemaX LavAdvantage SPEX3512T has overvoltage?
    • S
      Sonya ColeAug 30, 2025
      If your EemaX Water Heater is experiencing overvoltage, it means the inlet voltage is too high compared to the heater's specifications. Provide voltage within specified range.
  • E
    Elizabeth HunterAug 31, 2025
    What causes residual heat in EemaX Water Heater?
    • P
      Phillip FranklinAug 31, 2025
      Residual heat in your EemaX Water Heater, indicated by an elevated internal water temperature without flow, is caused by both triacs failing closed. To solve this, run water through the unit.
  • E
    Elizabeth VillegasSep 2, 2025
    What to do if EemaX LavAdvantage SPEX3512T Water Heater has inlet thermistor failure?
    • J
      Jessica BrownSep 2, 2025
      If your EemaX Water Heater is showing an inlet thermistor failure, this is because the inlet thermistor is interrupted or disconnected. Inspect the connections/wiring of the inlet thermistor.
  • E
    edwardmartinSep 4, 2025
    What to do if EemaX Water Heater has outlet thermistor failure?
    • B
      Brett MunozSep 4, 2025
      If your EemaX Water Heater is showing an outlet thermistor failure, this is because the outlet thermistor is interrupted or disconnected. Inspect connections/wiring of outlet thermistor.
  • J
    Jasmine ShahSep 6, 2025
    What to do if my EemaX LavAdvantage SPEX3512T Water Heater shows overvoltage?
    • S
      Susan DavisSep 6, 2025
      If your EemaX Water Heater indicates overvoltage, it means the inlet voltage is too high compared to the heater's specifications. Have certified personnel check the inlet voltage and ensure it's within the specified range.

Summary

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

Emphasizes reading all instructions before proceeding with installation or service.

GENERAL

MOUNTING THE UNIT TO THE WALL

PLUMBING HOOK-UP

ELECTRICAL HOOK-UP

ELECTRICAL SPECIFICATIONS

Provides voltage, power, current, and wire size requirements for different models.

COMMISSIONING THE HEATER

UNIT OPERATION

SETTING TEMPERATURE

Details how to adjust the water temperature using the unit's buttons.

ADVANCED FUNCTIONS

Explains how to access and navigate advanced settings like flow rate and inlet temperature.

ERROR CODES & UNITS

TROUBLESHOOTING

PERIODIC MAINTENANCE

PART NUMBERS FOR FITTINGS, AERATORS AND AERATOR ADAPTORS

REPAIR PARTS FOR LavAdvantage UNITS

EemaX LavAdvantage SPEX3512T Specifications

General IconGeneral
ModelSPEX3512T
CategoryWater Heater
BrandEemaX
TypeTankless
Power SourceElectric
Voltage240V
Wattage3.5 kW
Weight4 lbs
CertificationUL
Flow Rate0.5 GPM