INSTALLATION GUIDE AND OWNER’S MANUAL
LavAdvantage™
ELECTRIC INSTANTANEOUS WATER HEATERS

Questions and Answers

  • T
    Teresa BryantAug 20, 2025
    What to do if my EemaX LavAdvantage SPEX95T has no heat?
    • K
      Kimberly Cain DDSAug 20, 2025
      If your EemaX Water Heater isn't producing heat, the cause may be element failure, a tripped or malfunctioning ECO, failed open triac(s), a malfunctioning relay/contactor, control board failure, or an out-of-spec inlet water supply. You can measure element resistance with the unit completely turned off to troubleshoot.
  • D
    David HuangAug 22, 2025
    What to do if EemaX LavAdvantage SPEX95T Water Heater has undervoltage?
    • E
      Edwin BondAug 22, 2025
      If your EemaX Water Heater is experiencing undervoltage, it indicates that the inlet voltage is too low compared to the heater's specifications. Provide voltage within specified range.
  • R
    Robert PerkinsAug 25, 2025
    Why is my EemaX LavAdvantage SPEX95T Water Heater producing low heat?
    • J
      James SmithAug 25, 2025
      Low heat from your EemaX Water Heater can stem from undervoltage, failed open triac(s), control board failure, or inlet/outlet thermistor(s) failure. Verify the power supply (voltage) while the heater is running to address this issue.
  • R
    richardsoncliffordAug 26, 2025
    What to do if EemaX LavAdvantage SPEX95T flow is too high?
    • B
      Billy MitchellAug 26, 2025
      If the flow in your EemaX Water Heater is too high, preventing the water from heating to the setpoint temperature, reduce the flow. You can achieve this by using an outlet flow restrictor or a faucet aerator.
  • A
    Angela JohnstonAug 28, 2025
    What to do if EemaX LavAdvantage SPEX95T Water Heater shows freeze warning?
    • I
      Isaac BarnesAug 28, 2025
      If your EemaX Water Heater displays a freeze warning, it means the inlet temperature is too low (below 35°F). To resolve this, increase the temperature of the inlet water to meet product specifications.
  • J
    John NguyenAug 29, 2025
    What to do if EemaX LavAdvantage SPEX95T has overvoltage?
    • A
      alexnavarroAug 29, 2025
      If your EemaX Water Heater is experiencing overvoltage, it means the inlet voltage is too high compared to the heater's specifications. Provide voltage within specified range.
  • D
    David RossAug 31, 2025
    What causes residual heat in EemaX Water Heater?
    • B
      Bryan BooneAug 31, 2025
      Residual heat in your EemaX Water Heater, indicated by an elevated internal water temperature without flow, is caused by both triacs failing closed. To solve this, run water through the unit.
  • B
    Bradley JonesSep 2, 2025
    What to do if EemaX LavAdvantage SPEX95T Water Heater has inlet thermistor failure?
    • W
      wfoxSep 2, 2025
      If your EemaX Water Heater is showing an inlet thermistor failure, this is because the inlet thermistor is interrupted or disconnected. Inspect the connections/wiring of the inlet thermistor.
  • J
    Joshua MolinaSep 4, 2025
    What to do if EemaX LavAdvantage SPEX95T Water Heater has outlet thermistor failure?
    • N
      nicholsonfrankSep 4, 2025
      If your EemaX Water Heater is showing an outlet thermistor failure, this is because the outlet thermistor is interrupted or disconnected. Inspect connections/wiring of outlet thermistor.
  • S
    Steven BlackSep 6, 2025
    What to do if my EemaX LavAdvantage SPEX95T Water Heater shows overvoltage?
    • Z
      Zachary RodriguezSep 6, 2025
      If your EemaX Water Heater indicates overvoltage, it means the inlet voltage is too high compared to the heater's specifications. Have certified personnel check the inlet voltage and ensure it's within the specified range.

Summary

Safety and General Information

Important Safety Instructions

Crucial safety precautions and warnings before installation and operation.

General

Overview of heater placement, performance, and model specifics.

1) Mounting the Unit to the Wall

2) Plumbing Hook-Up

3) Electrical Hook-Up

4) Commissioning the Heater

5) Unit Operation

Setting Temperature

Instructions for adjusting water temperature using control buttons.

Advanced Functions and Error Codes

Accessing advanced settings, error codes, and unit status information.

6) Troubleshooting

7) Periodic Maintenance

8) Part Numbers for Fittings, Aerators and Aerator Adaptors

9) Repair Parts for LavAdvantage Units