6) TROUBLESHOOTING
CAUTION: Make certain power to unit is “OFF” before removing protective cover FOR ANY REASON.
For status code details, please consult the table below.
Code
Name
Possible causes
Heater response
Possible solutions
F23
No heat
- element failure
- ECO tripped/malfunctioning
- triac(s) failed open
- relay/contactor malfunctioning
- control board failure
- inlet water supply out of spec
Heating will be disabled after
30 seconds of continuous no
heat condition.
- measure element
resistance with the unit
completely turned off
F24
Low heat
- undervoltage
- triac(s) failed open
- control board failure
- inlet/outlet thermistor(s) failure
Heating enabled, reduced
performance (lower outlet
temperature).
- verify power supply
(voltage) while heater is
running
F33
Residual heat
- internal water temperature elevated
without flow
- both triacs failed closed
Heating disabled until outlet
temperature falls below the
reactivation temperature
(see default parameters
table).
- run water through the unit
F34
Overvoltage
- inlet voltage is too high compared to
the stated heater specifications
Heating enabled, reduced
performance (higher outlet
temperature).
- have certified personnel
verify the inlet voltage
- provide voltage within
specified range
F36
Undervoltage
- inlet voltage is too low compared to
the stated heater specifications
Heating enabled, reduced
performance (lower outlet
temperature).
- have certified personnel
verify the inlet voltage
- provide voltage within
specified range
F38
High flow
- flow is too high to heat the water to
setpoint temperature
Heating enabled, unit
operates as intended (lower
outlet temperature
possible).
- reduce flow (outlet flow
restrictor, faucet aerator)
F47
Inlet thermistor
failure
- inlet thermistor interrupted or
disconnected
Heating enabled based on
default inlet temperature
setting (see default
parameters table;
higher/lower outlet
temperature possible).
- inspect connections/wiring
of inlet thermistor
F48
Outlet
thermistor
failure
- outlet thermistor interrupted or
disconnected
Heating enabled, auto
calibration disabled.
- inspect connections/wiring
of outlet thermistor
F64
Freeze warning
- inlet temperature is too low (below
35°F)
Heating disabled while
condition is present.
- increase inlet water
temperature above 35°F
Still having trouble? Please call our Technical Service Department.