COMMISSIONING
Note
Before connecting your panels to SolMate®, please check the open circuit voltage (OCV). You can
find this value on the nameplate on the back of your panels. Depending on the open circuit
voltage, select the appropriate commissioning guide.
Note
If you are connecting your own panels, please ensure that the input voltage does not exceed 44V
and that you connect them in parallel only, not in series.
CONNECTING STANDARD PANELS AND SOLMATE®
Guide for Panels with an Open Circuit Voltage of More than 22V / max. 44V
1. Remove the magnetic cover of the connection box (on the back of the storage unit).
2. Now connect one end of the power cable to SolMate®.
3. Plug the other end into a power outlet (protective contact).
4. Then connect the storage unit and the panels using the PV connection cable with the attached
1.
4.
4.1
2. 3.
*
max. 44V
Guide for Panels with an Open Circuit Voltage of more than 22V and
MC4 Y-adapter (2-to-1) for parallel wiring. (Using the second PV input, you can connect up to two
additional panels with an extra connection cable (see Fig. 4.1).)