EFKA AB320A5200
56
6 List of Parameters
6.1 Preset Values Depending on Mode
The preset values which are different in the various modes are listed in the table below. When switching the mode by
means of parameter 290, these values change automatically.
Operator Level
Mode !
!!
!0 2 3 4 5 6 7 8 9101415161720212324
Parameter
000 - ----------630-----
001 - - - 2 - - - - - 2 - 2 17 - - - - -
002 - ----------102---3-
003 - ----------1018---3-
004 - -----0----250----35
005 - --0------------0-
007 - ---------------10-
008 - -----4---------2-
009 - -----1----11----1
013 - ------00--0------
014 - 0----000--00-0-0-
019 - -----2----221---3
021 - ----------23------
Technician Level
Mode !
!!
! 0 2 3 4 5 6 7 8 9101415161720212324
Parameter
100 - --------1--------
** 110 - - - 180 - - - 250 250 180 - - - - - - 180 -
** 111 - - - 5000 - - - - - 4500 - 7500 3800 - 2500 5500 4800 5000
** 112 - - - - - - - - - - - - 3800 - 600 - 1700 -
** 113 - - - - - - - - - - - - 3800 - 600 - 1700 -
**114 - ---------------1700 2000
** 115 - - - - - - - - - 700 - - - - - - 800 -
**116 - ---------------180-
** 117 - - - - - - - - - - - 9900 - - 1800 - 2000 9900
**118 - -------------2500 - 3000 -
119 - -----------1----
** 122 - - - - - - - - 6000 ---------
**123 - -------------2400 - - 9900
130 - -----1-----1-----
131 - ----------1------
132 - -----0----00----0
134 - - - - - - - - -1 - - - -1 -1 -
135 - -------------1---
137 - --------------111
152 - ---------------100-
153 - ---------0-----06-
158 - ----------------100
161 - - -0000000 -000-0 -0
180 - --------14----45-14-
181 - - - - - - - - - 230 - - - - - - 0 -
182 - -----1--1--1-1---
184 - -----------------
190 - --0--2-----1-----
192 - -----1----11-----
194 - -----------1-----
196 - ---------------0-
197 - ------------360----
x = The positions marked with ”x“ are not used in the functional sequence!