LOW
RPM
Underspeed Deviation from the target speed. If the speed falls below this minimum
speed, the feeder is stopped to allow the blade shaft to reach its target
speed again. The minimum speed can be entered both as an absolute
value and as a percentage deviation from the target speed. To enter a
percentage deviation, use the minus button (down arrow) to go past
zero. A percentage value is indicated in the display by a "%". For ex-
ample, "5%" corresponds to a percentage deviation of 5%. If the dis-
play shows "0850", for example, this means that 850 rpm has been
programmed as the minimum speed. If a "zero" is entered for this pa-
rameter, the minimum speed is not monitored.
Permitted value: 0 - 99 % or 0 - 5000 rpm
Over
RPM
Overspeed Upper permissible speed of the blade shaft. If this speed is reached or
exceeded, the feed rollers are stopped. The entry can be a percentage
or an absolute value, depending on the procedure for entering the
minimum speed. If a "0" is entered for this parameter, the overspeed is
not monitored.
Permitted value: 0 - 99% or 0 - 2700 rpm
IPR rotor
Pulses per
rotation
Number of pulses emitted by an initiator per revolution of the blade
shaft.
Permitted value: 1 - 60
Confirm
start
Confirm start Selection of whether the initial start of the feed must be confirmed with
"set" for increased operator safety.
Permitted value: Off/On
RPM-
sensor
NPN/PNP With the selection NPN/PNP the frequency input can be configured to
the type of input signal.
Set PW
Set password Set password to access the parameter menu.
Permitted value: 0000 - 9999
Daily
pass-
word
Password for the
daily operating
hours counter
Set password for resetting the daily operating hours counter.
Permitted value: 0000 - 9999
Factory
setting
Factory setting Reset HC960 to factory settings. No. shows how often the option has
already been used.
Permitted value: No/Yes
Set total
hours
Set total hours Set total operating hours.
Permitted value: 00000 - 99999
Lan-
guage
Language set-
tings
Setting the language
Permitted value:
Exit
Exit Exit parameter menu: