Cause Solution
Filter location. The top edge of the pump head should be at least 10 cm beneath
the surface of the water. It is better to place it underneath the
aquarium.
Air is being sucked in via the
hose installation.
Checkthathoseconnectoristtedproperly,andmaybecheck
whether hoses leak.
Additional air supply
(membrane pump).
Do not install diffuser in the vicinity of the suction pipe.
Filter media heavily soiled. Cleanltermedia.
Filter media have been
placed in net bags.
Neverputlong-termltermediainnetbagsornylonstockings.This
leads to a drastic reduction in pump performance within a short time.
...Airinthelter
Cause Solution
Ceramic sleeve not or
incorrectly installed.
Correctly install or, if required, replace the ceramic sleeve.
Ceramic axis broken. Replace the ceramic axis.
... the pump causes loud operating noise
8.Que faire si...
Cause Remède
Lespaniersltrantsn‘ont
pas été mis en place
correctement .
Introduisezlespaniersltrantsetlepréltredetellemanièreque
la surface verticale formée par leur superposition soit parfaitement
plane.
Paniersltrants
excessivement remplis.
Neremplissezpaslespaniersltrantsàl‘excès.Nettoyezlecas
échéant les bords supérieurs et inférieurs des paniers entrant en
contact les uns avec les autres.
Cloison séparatrice
incorrectement montée.
Insérezlacloisonséparatricedanslacuvedultre,jusqu‘àce
qu‘elle encrante correctement.
Lejointprolén‘estpas
correctement monté.
Montez le joint correctement dans la rainure prévue à cet effet sur la
partiesupérieuredultre.Vériezquelejointn‘estpasendommagé.
Remplacez-le le cas échéant.
...Lapartiesupérieuredultrerefusedesefermer
Danger !
Lorsdetravauxeffectuéssurleltre,veilleràcequelesjonctionsélectriquesrestentausec.
Débrancherlachesecteur!Encasdeproblème,consulternotresiteInternetwww.eheim.de.