17
On surfaces that are usually warmer or colder than the rest of the room. Due to the
temperature differences, smoke or heat may not reach the alarm.
Next to or directly over heating devices or air-conditioners, windows, wall vents, etc.,
which change the direction of air flow.
In very high or inconvenient areas (e.g. above staircases) where the alarms are hard
to reach (for testing and silencing purposes).
Position the alarm at least 1 m away from dimmable lights and their wiring, as some
dimmers can cause faults.
Position wire-linked alarms at least 1.5 m away from fluorescent tubes and lay the
cables at least 1 m away, as the
device may be impaired by electrical “interference”
and/or flickering.