EasyManuals Logo

Ei Electronics Ei650iRF User Manual

Ei Electronics Ei650iRF
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
13
2.3 Positioning
Installation on the ceiling
Hot smoke rises and spreads across the ceiling of a room. Because of this, it is
recommended that you choose a central position on the ceiling for installing smoke
alarms. The air “stands still” in corners and does not circulate, therefore smoke alarms
should never be installed in corners. Place the alarm at least 0.5 m away from walls and
corners. Place the alarm at least 0.5 m away from lights or other decorative objects that
could obstruct the smoke's penetration into the smoke alarm. In rooms and hallways less
than 1 m wide, the smoke alarm should be installed in the centre of the ceiling between
the walls (see Figure 3).
Fig. 3
> 0.5 m
> 0.5 m
Installation in
the centre of
the ceiling
Fig. 4
< 6 m
Maximum room
height 6 m

Other manuals for Ei Electronics Ei650iRF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ei Electronics Ei650iRF and is the answer not in the manual?

Ei Electronics Ei650iRF Specifications

General IconGeneral
BrandEi Electronics
ModelEi650iRF
CategorySmoke Alarm
LanguageEnglish

Related product manuals