GB
- 17 -
Sound and vibration values were measured in
accordance with EN 60335-1.
L
pA
sound pressure level ........................ 77 dB(A)
K
pA
uncertainty .............................................3 dB
L
WA
sound power level .......................... 94 dB(A)
K
WA
uncertainty .............................................3 dB
The impact of noise can cause damage to hea-
ring.
Total vibration values (vector sum of three direc-
tions) determined in accordance with EN 60745.
Vibration emission value a
h
≤ 2.5 m/s
2
K uncertainty = 1.5 m/s
2
The specied vibration value was established in
accordance with a standardized testing method. It
may change according to how the electric equip-
ment is used and may exceed the specied value
in exceptional circumstances.
The specied vibration value can be used to
compare the equipment with other electric power
tools.
The specied vibration value can be used for initi-
al assessment of a harmful eect.
•
Only use appliances which are in perfect wor-
king order.
•
Service and clean the appliance regularly.
•
Adapt your working style to suit the appliance.
•
Do not overload the appliance.
•
Have the appliance serviced whenever ne-
cessary.
•
Switch the appliance off when it is not in use.
•
Wear protective gloves.
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
tion is used.
3. Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.
•
The pressure cleaner must be stood on a le-
vel, stable surface.
•
It is recommended that you adopt the correct
operating position every time you use the
equipment, with one hand on the gun and the
other on the lance.
•
Never direct the water jet at electrical lines or
the equipment itself.
•
So that the pump does not suffer any damage
when it is not in use, a small amount of leaka-
ge from the pump is normal.
•
Never use the machine in potentially explosi-
ve areas under any circumstances!
•
The operating temperature must be between
+5 and + 60°C.
•
Do not cover or modify the lance or the spray
nozzles in any way.
•
The pressure cleaner is designed to be used
with cold or lukewarm water (max. 60 °C);
higher temperatures can damage the pump.
•
Do not use water that is dirty, gritty or con-
tains any chemical products, as these could
impair operation and shorten the life of the
equipment.
Assemble the pressure cleaner as shown in Fi-
gure 2-6.
Anleitung_BT_HP_1435_SPK1.indb 17 28.09.11 19:46