11. Troubleshooting
Fault Cause Remedy
Feed roller does
not turn
- Power supply not connected
- Wire feed controller set to 0
- Check connection
- Check setting
Feed roller turns,
but does not feed
any wire
- Incorrect roller pressure (see 5.3.3)
- Roller brake set too rmly (see
5.3.3)
- Dirty / damaged feed roller (see
5.3.3)
- Damaged hose package
- Contact tube wrong size / dirty /
worn (see 5.3.3)
- Welding wire welded to the gas
nozzle / contact tube
- Check setting
- Check setting
- Clean or replace
- Check the wire guide jacket
- Clean or replace
- Release
After a lengthy
period of use the
welding set does
not work any longer,
the thermostat (3)
control light is lit
- The welding set has overheated
due to being used for too long and
a failure to observe the reset time
- Leave the set to cool down for at
least 20 – 30 minutes
Very poor weld - Incorrect current / feed setting (see
6.1.1/6.1.2)
- Check setting
Anl_TC_FW_100_SPK7.indb 27Anl_TC_FW_100_SPK7.indb 27 19.07.2017 09:51:0919.07.2017 09:51:09

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the EINHELL TC-FW 100 and is the answer not in the manual?

EINHELL TC-FW 100 Specifications

General IconGeneral
BrandEINHELL
ModelTC-FW 100
CategoryWelding System
LanguageEnglish

Related product manuals