10. Troubleshooting
Fault Possible cause Remedy
Engine does not
start
Automatic oil cut-out has not
responded
No fuel
Check the oil level, top up with engine
oil
Refuel
Generator has too
little or no
voltage
Controller or capacitor defective
Overcurrent circuit-breaker has
triggered
Air lter dirty
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
Clean or replace the lter