EKO INSTRUMENTS CO., LTD. I-V Curve Checker MP-11 Instruction Manual Ver.7
Setup the Measurement Parameters:
Check [Use Sensor Unit]
Auto or Manual Measurement Setting
Measurement Range
Select Irradiance Sensor Type
Enter Pyranometer/Reference Cell constant value
PV module/array parameter settings
Specify data saving settings
While the power is turned ON, connect the MP-11 to PV module/array.
Display and analyze the measured data
Disconnect the PV module/array from MP-11 while the power is still turned ON.
Turn the MP-11 Main Unit power OFF.
Turn the Sensor Unit power OFF.
Disconnect the thermocouple cables from the Sensor Unit
Disconnect the External Pyranometer from the Sensor Unit
Disconnect the Sensor Unit from MP-11 Main Unit.
Remove the grounding cable from MP-11 Main Unit.
Disconnect the MP-11 Main Unit from the PC.
Exit the MP-11 I-V Checker Software and shut down the PC.
Return the components, such as the Sensor Unit, thermocouple cables, and PV
probes back in their places.
Reconnect the power conditioner and other related devices which were
disconnected before taking measurement with MP-11.