Impression 444 – Owner's manual
28
Close fuel supply valves and cylinder valve when appliances are not in use. Close valves
immediately in an emergency.
Be sure appliance valves are closed before opening cylinder valve.
Close gas supply valves and cylinder valve when appliances are not in use. Close valves
immediately in an emergency.
Test the LPG system before each use;
- With appliance valve closed, open the cylinder valve
- Close cylinder valve
- Allow indicated gauge pressure to stabilize
- Observe pressure on gauge for 3 min
- If pressure remains constant, no leak present.
If pressure drops, a leak exists. Do not use LPG system until leak
is repaired
Test the LPG system regularly; check all connections for leakage by manual look-testing or by
testing with soapy water or detergent solution (with appliance burner valve closed and
cylinder and system valves open). If leakage is present, close cylinder valve and have the
system repaired before further use. System repairs should be made by a competent person.
DO NOT use solutions containing ammonia.
NEVER USE FLAME TO CHECK FOR LEAKS!
Figure 13