12
F EEDER C ABLE S EC TIO N
Ty p e “H 0 5 R R - F ”
220-240 Vac 3 x 1,5 mm
2
(*) (**)
(*) Connection possible with plug and outlet
(**) Connection with wall box connection.
C O NNEC TIO N O F TH E P O W ER S UP P LY C ABLE
W AR NING : If t h e p o w e r s u p p l y c a b l e i s d a m a g e d , i t m u s t b e r e p l a c e d o n l y b y a n
a u t h o r i s e d s e r v i c e a g e n t i n o r d e r t o a v o i d a h a za r d .
• Unhook the terminal board cover by inserting a screwdriver into the two hooks “A
”
(g.
2.1).
• Unscrew the screw “D” and open completely the cable clamp “E” (g. 2.2).
• Connect the phase, neutral and earth wires to terminal board “G ” according to the
diagram in g. 2.3.
• Strain the feeder cable and block it with cable clamp “E” (by screwing screw “D”).
• Close the terminal block cover (check the two hooks “A” are correctly hooked).
IMPORTANT: To connect the power supply cable DO NOT unscrew the screws xing
t h e c o v e r p l a t e b e h i n d t h e t e r m i n a l b l o c k .
NO TE: Th e e a r t h c o n d u c t o r m u s t b e l e f t a b o u t 3 c m l o n g e r t h a n t h e o t h e r s .
1
2
3
5
4
N
L2
PE
L1
G
D
E
PE
N
L
Fig. 2.3
Fig. 2.2
2 2 0 - 2 4 0 V a c
A
Fig. 2.1