Bedieningshandleiding
Voor de gespecialiseerde vakman
Aangeblazen gasbrander
Operating instructions
For specialist installation engineers
Gas burners
VG 1.105 D E
de, fr, it............................ 4200 1092 1300
nl, en................................ 4200 1092 1400
de, fr, it, nl, en................. 4200 1092 1100

Questions and Answers

  • A
    Adam JohnsAug 7, 2025
    Why elco VG 1.105 D E Indoor Fireplace burner does not start after thermostat shutdown?
    • D
      Dustin PittmanAug 7, 2025
      If the elco Indoor Fireplace burner does not start after a thermostat shutdown and there's no malfunction indicated on the automatic combustion control unit, it could be due to a drop in supply voltage, a power failure, or a control unit malfunction. Check the cause of the fall in voltage or the power failure. If the problem persists, replace the control unit.
  • S
    Sara WilliamsAug 12, 2025
    Why does elco VG 1.105 D E Indoor Fireplace burner switch off during operation?
    • D
      Dr. Melanie SalazarAug 13, 2025
      If the elco Indoor Fireplace burner switches off during operation, the air pressure switch contact may be opening during start-up or operation. Adjust or replace the pressure switch to resolve this issue.
  • K
    kjonesAug 17, 2025
    What to do if elco Indoor Fireplace burner blower starts but burner does not start?
    • J
      Jacob EllisonAug 17, 2025
      If the elco Indoor Fireplace burner blower starts up, but the burner does not start, it could be because the air pressure switch contact does not close. Check the pressure transmitter for foreign bodies and examine the wiring.
  • T
    teresa13Aug 22, 2025
    What causes elco Indoor Fireplace burner to switch off during operation?
    • C
      catherine55Aug 22, 2025
      If the elco Indoor Fireplace burner switches off during operation, check the ionization sensor circuit. You may also need to check or replace the automatic combustion control unit.
  • R
    rrodriguezAug 27, 2025
    What to do if elco Indoor Fireplace burner does not start?
    • K
      Kenneth McdonaldAug 27, 2025
      If the elco Indoor Fireplace burner does not start, it might be because the air pressure switch is not in the rest position, is incorrectly adjusted, or the contact is welded. Readjust or replace the pressure switch.
  • D
    Deborah CombsNov 1, 2025
    What to do if the elco VG 1.105 D E Indoor Fireplace burner starts then fails?
    • M
      matamarciaNov 2, 2025
      If the elco Indoor Fireplace burner starts, the ignition switches on, but then fails, it could be due to several reasons. There might be no flame after the safety time, the gas throughput could be set incorrectly, or there might be a malfunction in the flame monitoring system. Other potential causes include no ignition sparks, short-circuited electrode(s), a damaged or defective ignition cable, a defective ignition transformer, a faulty automatic combustion control unit, solenoid valves that don't open, or valves that are jamming. To resolve this, adjust the gas throughput. Check the condition and position of the ionization sensor. Inspect the connections of the ionization circuit. Adjust, clean, or replace the electrode(s). Connect or replace the cable(s). Replace the transformer or the c...

Summary

MB-ZRDLE gas train

Pressure regulator setting

Procedure for adjusting the gas pressure regulator.

Setting the gas throughput for the 2 nd stage

Procedure for adjusting the gas throughput for the 2nd stage.

Setting the gas throughput for the 1 st stage

Instructions for adjusting the gas throughput for the 1st stage.

DMG 972-N automatic combustion control unit

Blink code explanation

Explains the meaning of different blink codes from the control unit.

Allocation chart Connection socket

Terminal designation table

Lists terminal numbers and their corresponding designations.

Operating mode

Safety function

Explanation of safety functions and shutdown procedures.

Burner assembly

Burner installation position

Details on burner flange dimensions and installation depth adjustment.

Liquefied Petroleum Gas operation

Burner boiler electrical connection

Safety notes and connection details for burner-boiler electrical interface.

Checks before start-up

Testing the burner program sequence

Procedure to test the burner program sequence before initial gas release.

Ionisation current measurement

Method for measuring ionisation current, required minimum value.

Adjustment data

Setting the burner

Setting the air pressure switch

Setting the gas pressostat

Procedure for setting the gas pressostat shut-off pressure.

Operating check

Procedures for checking flame monitoring and safety functions.

Maintenance

Troubleshooting

Fault diagnosis and repair

Initial checks for correct operation prerequisites before diagnosing faults.

Malfunction table

Table listing malfunctions, their causes, and recommended remedies.