NOTES
• If a permanent drainage pipe is fitted the unit will not stop operating. Setting the desired humidity
to around 35% is good for laundry mode, a quick drying boost, or in emergencies. It is not
recommended for long normal operation in a domestic or office environment.
• To allow more moisture in the air, set a higher desired humidity (e.g. 60-70%).
• We recommend setting the desired humidity to 50-55%. This is great for domestic operation and
dry storage
• Setting the humidity to 60% is great for personal comfort and applications where 50% RH is
considered too dry
• Setting the humidity to 70% is ideal for unoccupied properties or where an economical run is needed
without the need to reduce the humidity further.
OTHER FEATURES AND INDICATORS
TANK FULL LIGHT
When the water tank is full, removed or incorrectly inserted the unit will stop dehumidifying, the tank full
light will illuminate and the unit will bleep. Empty the tank and reinsert it correctly to resume operation.
AUTO DEFROST
When frost builds up on the evaporator coils, the compressor will cycle off and the unit will go in to defrost
mode. Following completion of the defrost mode, the unit will return to the previously operating settings.
• When the unit is running in a room with a temperature between 0℃ and 12℃,it will enter
defrost mode for 8 minutes roughly every 30minutes.
• When the unit is running in a room with a temperature between 12℃ and 16℃,it will enter
defrost mode for 5 minutes roughly every 60minutes.
• When the unit is running in a room with a temperature between 16℃ and 20℃,it will enter
defrost mode for 5 minutes roughly every 90minutes.
AUTO MODE
• When the humidity of the room is 5% lower than the desired humidity the compressor will turn off
automatically but the fan will continue to operate to ensure that the air within the room is not stale.
The unit will use only a minimal amount of energy in fan mode.
• When the humidity of the room is 5% higher than the desired humidity the compressor will restart
after a 3 minutes delay to protect the compressor.
POWER
After the unit has stopped, to protect the compressor it is not recommended to resume operation for at
least 10 minutes. Operation can resume after this period lapses. When the unit is restarted there is a 3
minutes delay before compressor will start.