EasyManua.ls Logo

Electro-Voice P900RL - TECHNICAL SPECIFICATIONS

Electro-Voice P900RL
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
29
SPECIFICATIONS / TECHNISCHE DATEN
P900RL
P1200RL
Load Impedance
8
4
2
8
2
Maximum Midband Output Power
THD = 1%, 1kHz
2x
280W
2x
450W
2x
650W
2x
380W
2x
600W
2x
850W
Rated Output Power
THD < 0.2%, 20Hz ... 20kHz
2x
175W
2x
350W
-
2x
250W
2x
500W
-
Max. Single Channel Output Power
Dynamic-Headroom, IHF-A
340W
640W
720W
460W
880W
950W
Maximum RMS Voltage Swing
THD = 1%, 1kHz
56V
64V
Power Consumption
at 1/8 maximum output power @ 4
690W
870W
THD at rated output power,
MBW = 80kHz, 1kHz
< 0.05%
IMD-SMPTE
60Hz, 7kHz
< 0.08%
DIM30
3.15kHz, 15kHz
< 0.03%
Crosstalk Attenuation
ref. 1kHz, at rated output power
> 80dB
Frequency Response
-1dB, ref. 1kHz
15Hz ... 22.5kHz
Damping Factor
at 100Hz / 1kHz, 8
> 300 / > 200
Signal to Noise Ratio, Ampli er
A-weighted
106dB
Signal to Noise Ratio, System
A-weighted
100dB
Input Sensitivity
at rated output power @ 4
, 1kHz
+6dBu (1.55V)
Max. Input Voltage
+21dBu (8.7V)
Input Impedance
20Hz ... 20kHz, balanced
20k
CMR
1kHz
80dB
Output Voltage
DSP OUT / Monitor
rated: +6dBu (1.55V)
max: +21dBu (8.7V)
Output Impedance
DSP OUT / Monitor
< 100
Minimum Output Load
DSP OUT / Monitor
600
Digital Signal Processing
AD & DA Conversion
24 Bit, Sigma-Delta, 128 x Oversampling, Linear Phase
Sample Rate
48kHz
Internal Wordlength
48 bit
Dynamic Range
115dB (typical)
Functions
Volume Control, Routing,
X-Over
(6, 12, 18, 24 dB/Oct Slope, Butterworth, Bessel, Linkwitz-Riley)
,
Filter
(Parametric EQ, Lo / Hi Shelving EQ, LPN, Lo / Hi Pass, Allpass)
,
Compressor / Limiter,
Delay
- System (ampli er) at rated conditions, both channels driven, 8
loads, unless otherwise speci ed.
- Depending on the ambient temperature, the unit might not operate continuously at 2
load.