Cabinets: 4 x Xi 1122, 4 x XI 2181 Horizontal coverage: 2 x 100°-160°
Amps: 4 x P 3000 Average distance: 20-25 meters
Cabeling: 2 x NL4 long/short, 2 x NL8 long/short Total amp. power: 6,400 Watts (cont.)
Dx38: 2
P3000 can be used through out.
L: 12” L:2”
L: 2 x 18 “ L: 2 x 18 “
Equipment Capacity
Dx 38 configuration * OS V1.05, might change w/o prior notice
Comments Options
System Applications Xi Series
3-Way Stereo
Clubs, Smaller Venues, Top 40 Bands
3.2
Left Spare
L: 12” L:2”
L: 2 x 18 “ L:2 x 18 “
Spare Right
Dx38 In 1 In 2 Out 1 Out 2 Out 3 Out 4 Preset *
#1 Main Left Lo L Mid L Hi L #36 (change Out1 to 2181-see#42)
#2 Main Right Lo R Mid R Hi R #36 (change Out1 to 2181-see#42)
Xi 1122 could be positioned for dedicated horizontal
angles
Xi 1122
Xi 1122
Xi 1122
Xi 1122