- 16 -
03.2004 R.K. 599 519 400 EN
Water inlet, lift off cover, unscrew nut
Salt filler neck
In Service Position, you can also remove or reinstall NTC/
trouble sensors, pressure monitors, and water softening
equipment.
To dismount the water softening equipment, remove electrical
connections.
Also detach the two hoses leading to the regeneration
dosage device.
Pull off the water inlet cap from the trough side, and unscrew
the nut located below.
Once the salt seal is unscrewed from the salt filling pipe, turn
off the large fastening nut.
A useful hint:
You could use a V-belt to loosen this nut, by applying it as
described in the figure below.
5.4 Softener