Technical Support - A.D.L. 11/70 599 74 23-12 Rev.00
Position 9
Drain, calibration of
analogue pressure
switch and spin.
Purpose of the test: To check the correct operation of the spin cycle
drain pump and calibrate the analogue pressure
switch.
Components activated:
Door safety interlock
• Drain pump
• Motor up to 650 rpm then at maximum spin
speed (**)
Working conditions:
Door closed
• Water level lower than anti-boiling level for
spinning
LCD display
Drum speed in rpm/10
Position 10
Drum position Purpose of the test: To check the correct position of the drum via DSP
Components activated:
Drum rotation motor.
• Door fastening device.
• Drum position sensor DSP.
Working conditions:
• Door closed.
LCD display
Position 11
Reading/Deleting the last
alarm
Purpose of the test: Reading/Deleting the last alarm
Components activated: -------------
Working conditions: -------------
LCD display
(*) In most cases, this time is sufficient to check the heating. However, the time can be increased by repeating
the phase without draining the water: pass for a moment to a different phase of the diagnostic cycle and
then back to the heating control phase (if the temperature is higher than 80°C, heating does not take
place).
(**) The check at the maximum speed occurs without control of the A.G.S. (Unbalancing Control Algorithm) and
no garments must be inside the appliance.