Technical Support - A.D.L. 10/70 599 74 23-12 Rev.00
Position 6
No command
Purpose of the test: -------------
Components activated:
-------------
Working conditions:
-------------
LCD display
Position 7
Heating Purpose of the test: To check the correct operation of the heater unit.
Components activated:
Door fastening device.
• Wash solenoid, if the water in the tub is not
enough to cover the heating element.
• Heating element.
Working conditions:
Door closed
• Water level high enough to cover the heating
element.
• Maximum time 10 mins up to 90°C. (*)
LCD display
Temperature in °C measured using the
NTC probe.
Position 8
Leaks from the tub Purpose of the test: To check for any water leaks from the tub during
operation.
Components activated:
Door fastening device.
• Wash solenoid, if the water in the tub is not
enough to cover the heating element.
• Motor (anticlockwise rpm, pulse at 250 rpm).
Working conditions:
Door closed.
• Water level above
• The heating element.
LCD display
Drum speed in rpm/10