Technical Support - A.D.L. 16/70 599 74 23-12 Rev.00
ALARM
CODE
Description Possible fault
Action
Machine status
Reset
E31
Malfunction in electronic pressure
switch circuit
• Wiring; Electronic pressure switch.
• Main electronic circuit board.
Cycle stops with door locked RESET
E32
Calibration error of the electronic
pressure switch
• Drain tube kinked/clogged/improperly positioned.
• Solenoid valve faulty.
• Drain filter clogged/dirty.
• Drain pump faulty.
• Leaks from pressure switch water circuit.
• Pressure switch defective;
• Wiring; main circuit board.
Cycle paused START/RESET
E35
Overflow
• Water fill solenoid valve faulty.
• Leaks from pressure switch water circuit.
• Faulty wiring.
• Pressure switch faulty.
• Main circuit board faulty.
Cycle interrupted.
Safety drain cycle.
Drain pump continues to operate (5 min. on, then
5 min. off. etc.)
RESET
E38
Internal pressure chamber is
clogged (water level does not
change for at least 30 sec. of
drum rotation)
• Motor belt broken.
• Pressure switch hydraulic circuit clogged.
Heating phase is skipped RESET