Technical Support - A.D.L. 16/70 599 74 23-12 Rev.00
ALARM
CODE
Description Possible fault
Action
Machine status
Reset
E31
Malfunction in electronic pressure
switch circuit
Wiring; Electronic pressure switch.
Main electronic circuit board.
Cycle stops with door locked RESET
E32
Calibration error of the electronic
pressure switch
Drain tube kinked/clogged/improperly positioned.
Solenoid valve faulty.
Drain filter clogged/dirty.
Drain pump faulty.
Leaks from pressure switch water circuit.
Pressure switch defective;
Wiring; main circuit board.
Cycle paused START/RESET
E35
Overflow
Water fill solenoid valve faulty.
Leaks from pressure switch water circuit.
Faulty wiring.
Pressure switch faulty.
Main circuit board faulty.
Cycle interrupted.
Safety drain cycle.
Drain pump continues to operate (5 min. on, then
5 min. off. etc.)
RESET
E38
Internal pressure chamber is
clogged (water level does not
change for at least 30 sec. of
drum rotation)
Motor belt broken.
Pressure switch hydraulic circuit clogged.
Heating phase is skipped RESET