EasyManua.ls Logo

Electrolux EWM09312 - Page 17

Electrolux EWM09312
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Support - A.D.L. 17/70 599 74 23-12 Rev.00
ALARM
CODE
Description Possible fault
Action
Machine status
Reset
E41
Door open
Check whether the door is closed properly
Faulty wiring.
Door safety interlock faulty
Main circuit board faulty.
Cycle paused
CLOSE THE
DOOR
E42
Problems with door lock
Faulty wiring.
Door safety interlock faulty.
Electrical current leak between heating element and ground.
Main circuit board faulty.
Cycle paused START/RESET
E43
Faulty Triac supplying power to
door delay system
Faulty wiring.
Door safety interlock faulty.
Main circuit board faulty.
Safety drain cycle.
Cycle blocked
RESET
E44
Faulty sensing by door delay
system
Main circuit board faulty.
Safety drain cycle.
Cycle blocked
RESET
E45
Faulty sensing by door delay
system Triac
Main circuit board faulty.
Safety drain cycle.
Cycle blocked
RESET
E51
Motor power Triac short-circuited
Faulty wiring.
Motor faulty;
Main circuit board faulty.
After 5 attempts, cycle blocked with door
unlocked.
ON/OFF
RESET
E52
No signal from motor tachometric
generator.
Faulty wiring.
Motor faulty.
Main circuit board faulty.
Cycle blocked with door locked after 5 attempts ON/OFF
E53
"Sensing" faulty Triac motor.
Input voltage to microprocessor
faulty.
Main circuit board faulty.
Cycle interrupted. RESET
E54
Motor relay contacts sticking
(high voltage level when the relay
switches to OFF).
Current leakage from the motor
Current leakage from the cabling
Main circuit board faulty.
Cycle blocked with door locked after 5 attempts. RESET

Related product manuals