Technical Support - A.D.L. 20/70 599 74 23-12 Rev.00
ALARM
CODE
Description Possible fault
Action
Machine status
Reset
E91
Communication error between
main PCB and display board
• Faulty wiring.
• Control/display circuit board faulty.
• Main circuit board faulty.
---------------- RESET
E92
Communication inconsistency
between main PCB and display
board. (incompatible versions)
• Incorrect control/display board.
• Incorrect PCB (does not correspond to the model)
Cycle blocked ON/OFF
E93
Appliance configuration error
• Main circuit board faulty.
• Incorrect configuration data.
Cycle blocked ON/OFF
E94
Incorrect configuration of
washing cycle
• Main circuit board faulty.
• Incorrect configuration data.
Cycle blocked ON/OFF
E97
Inconsistency between
programme selector and cycle
configuration
• Main circuit board faulty.
• Incorrect configuration data.
Cycle blocked RESET
E9C
Display board configuration error
• Display board faulty
----------------
START
ON/OFF
RESET
E9F
Communication error between
main board and display board
• Faulty wiring.
• Display board faulty.
• Main board faulty.
---------------- ON/OFF
EA1
No drum position signal made.
• DSP sensor faulty.
• Transmission belt broken.
• Main circuit board faulty.
• Faulty wiring.
Drum positioning cycle cancelled START/RESET
EA6
No signal from the DSP during
motor activation.
• DSP sensor faulty.
• Transmission belt broken.
• Main circuit board faulty.
• Faulty wiring.
Cycle paused.
START
RESET
EC1
Electronically controlled valve
blocked with operating flowmeter
• Faulty wiring.
• Solenoid valve faulty/blocked.
• Circuit board faulty
Cycle stops with door locked
Drain pump continues to operate (5 min. on, then
5 min. off. etc.)
RESET
EC4
AGS current sensor faulty
• Faulty wiring.
• Main board faulty.
Spin speed reduced to safety speed. RESET