Technical Support - A.D.L. 19/70 599 74 23-12 Rev.00
ALARM
CODE
Description Possible fault
Action
Machine status
Reset
E71
NTC probe for wash cycle faulty
(short-circuited or open)
• Faulty wiring.
• NTC probe for wash cycle faulty.
• Main circuit board faulty.
The heating phase is skipped START/RESET
E74
NTC probe for wash cycle
improperly positioned
• Faulty wiring.
• NTC probe for wash cycle improperly positioned.
• NTC probe faulty.
• Main circuit board faulty.
The heating phase is skipped RESET
E83
Error in reading selector
• Main circuit board faulty.
• Incorrect configuration data.
Cycle cancelled START/RESET
E86
Selector configuration error
• Incorrect configuration of display board.
----------------
START
ON/OFF
RESET
E87
Display board microprocessor
faulty
• Display board faulty.
----------------
START
ON/OFF
RESET