Electrolux EWM09312 - E44 Door Closed Sensing Fault; E45 Door Delay Sensing Circuit Fault

Electrolux EWM09312
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Support - A.D.L. 43/70 599 74 23-12 Rev.00
E44 E44: Door closed "sensing" circuit faulty E44
E45
E45: Problems with the "sensing" circuit of the component (Triac)
controlling the door delay system
E45
Replace the circuit board and repeat the diagnostic cycle to check for any further alarms.
Replace the circuit board and repeat the diagnostic cycle to check for any further alarms.
Check that all the connectors are correctly inserted
!
Check that all the connectors are correctly inserted
!
If there are burns on the circuit board,
see