11ENGLISH
5. INSTALLATION INSTRUCTIONS
Fig. 3
5.1 Exhausting hot air
In the COOLING Mode the appliance must
be placed close to a window or opening
so that the warm exhaust air can be
ducted outside� First position unit on a at
oor and make sure there’s a minimum of
30cm clearance around the unit, and is
within the vicinity of a single circuit outlet
power source�
1. Extend either side of the hose (Fig� 3)�
3. Install the window kit on the window
and slide the adaptor B into the window
slider kit and seal� (Fig� 5 & 6)
2. Slide the adaptor A into the exchange
hole of the unit as shown on Fig� 4�
Fig. 4
Fig. 5
Fig. 6
Window Slider Kit
Minimum: 56cm
Maxmum: 112cm
Refer to " 5.2 Installation in a
casement window" about how to
install the window kit�
The hose can be extended from
its original length of 38cm up to
150cm, but it is the best to keep
the length to minimum required�
Also make sure that the hose does
not have any sharp bends or sags�
(Fig� 7)
Fig. 7
5.2 Installation in a casement
window
Fig. 9
B
1. Open the window sash and lift the
locking lever of the window slider kit (Fig�
9)
B: Locking lever