9.2 General
May only be carried out by qualified personnel.
Mount a shut-off valve upstream from the machine.
The factory nozzle pressure setting corresponds to the fuel value given on the data label.
Check that the nozzle pressure and fuel value correspond with the values in the gas tables on the following pages. If
not, contact the supplier.
Bleed the pipe system before connecting the machine.
Note!
After connection all joints must be checked. There must not be any leaks.
9.3 Gas installation
This gas appliance is build to run on natural gas (group I2H and I2E), commonly identified by GNH.
Japan to run on LPG (group I3B/P) 2800 Pa inlet pressure, no regulation.
This default gas appliance is built to be installed at not over than 610 m (2001 ft) high altitude otherwise a kit for high
altitude must be installed to the machine. For the kit No. please refer to the spare parts list.
The data label shows the injector size and the injector pressure and the countries that use this gas quality:
AL Albania IS Iceland
AT Austria IT Italy
BE Belgium JP Japan
BG Bulgaria LT Lithuania
CH Switzerland LU Luxembourg
CY Cyprus LV Latvia
CZ Czech Republic MK Republic of Macedonia
DE Germany MT Malta
DK Denmark NL Netherlands
EE Estonia NEC Non-european countries
ES Spain NO Norway
FI Finland PL Poland
FR France PT Portugal
GB United Kingdom RO Romania
GR Greece SE Sweden
HR Croatia SI Slovenia
HU Hungary SK Slovakia
IE Ireland TR Turkey
You should check the kind of energy gas that is available in your place and check high altitude of the machine located
place.
There are many gas types of the same kind but the machine should be equipped with different kinds of nozzles de-
pending on the gas type.
For non-european countries check the heat value of the energy gas and compare it to the declared heat value of gas
in the attached label.