2014.06.25
Service manual
Selecta II
T4290, T4530, T4650,
T4900, T41200, T4300S, T4420S
TD30, TD50, TD60, TD75, TD77,
TD100, TD135, TD30x30, TD45x45
WD4130, WD4240
T4250 from machine no. 23350/0006970
T4350 from machine no. 23250/0003715
487 05 40 31/EN
Original instructions
Question and Answer IconNeed help?

Do you have a question about the Electrolux TD60 and is the answer not in the manual?

Electrolux TD60 Specifications

General IconGeneral
TypeTumble Dryer
Capacity6kg
Heat SourceElectric
Dimensions (Width)600mm
Dimensions (Height)85 cm

Summary

Safety Precautions

Switching to Programming Mode

Troubleshooting - General

Troubleshooting - Sensor Errors

E03 Input Sensor Short Circuit Analysis

Diagnostic steps for input sensor short circuit, involving resistance checks and PCB replacement.

E04 Output Sensor Short Circuit Analysis

Diagnostic steps for output sensor short circuit, involving resistance checks and PCB replacement.

E17 Input Sensor Disconnected Analysis

Diagnostic steps for input sensor disconnection, involving resistance checks and PCB replacement.

E18 Output Sensor Disconnected Analysis

Diagnostic steps for output sensor disconnection, involving resistance checks and circuit board replacement.

Troubleshooting - Motor Errors

E05 Fan Motor Overheat Analysis

Diagnostic steps for fan motor overheat, checking blockage, seized motor, and thermal protection.

E06 Drum Motor Overheat Analysis

Diagnostic steps for drum motor overheat, checking blockage, seized rotor, and thermal protection.

Troubleshooting - System Errors

E08 Machine Overheat Analysis

Diagnostic steps for machine overheat, checking thermostats, fuse, airflow, and temperature parameters.

E11 Drying Error RMC Analysis

Diagnostic steps for RMC drying error, checking connections, heating, and dryer fill level.

E12 Drying Error Autostop Analysis

Diagnostic steps for Autostop drying error, checking heating and dryer fill level.

E14 Gas Error Analysis and Resetting

Diagnostic steps for gas errors, including flame detection, ignition, and gas supply checks, plus resetting procedures.

E14 Gas Error Detailed Analysis

Detailed flowchart for diagnosing gas errors, checking flame sensor, spark, and gas supply.

E15 No Vacuum Detected Analysis

Diagnostic steps for no vacuum detected error, checking underpressure, fan motor direction, and AC voltage.

E16 Vacuum Sensor Short Circuit Analysis

Diagnostic steps for vacuum sensor short circuit, checking heat setting, AC voltage, and harness.