Program
Changing P-programs
Following parameters determine how eg. program P1 is executed.
Parameter Explanation
7.01 Residual moisture level in %.
7.10 Extra drying time, for how long the drying must carry on after 0%
is reached.
7.19 Time / Automatics, the program can be set with a specified time
period or with a non-time determined drying via the built-in
automatics.
7.28 Max outlet air temperature set-up, roughly represents
the temperature of the garments.
7.37 Drying time which might be set in 7.19.
7.46 Cooling down condition for temperature, the cooling down of
the garments stops when both conditions (7.46 / 7.55) are met.
7.55 Cooling down condition for time, the cooling down of the
garments stops when both conditions (7.46 / 7.55) are met.
7.64 Reversing during P-program on/off.
Example: Changing P1
ProgramP1canbeadjustedtotheindividualtextileswhicharetobeusedinthedryer.
The below example shows how to change the set up of program for drying thick lining
boiler suits in mixed fabric 65/35 with polyester lining.
7.01 00 factory setting = 00% is maintained
7.10 15 extra drying time is set to 15 min
7.19 01 automatic program is maintained
7.28 60 outlet air temperature is set to 60°C (140°F)
7.37 20 factory setting = 20 min is maintained
7.46 35 max outlet air temperature is set to 35°C (95°F)
7.55 10 cooling down time is set to 10 min
7.64 01 factory setting = 01 is maintained