55
Troubleshooting
Error analysis
E 14 - Gas error, push gas reset button
Gas resetting
See on the preprevious page.
E – 14
YES
Ventilate the gas system /
contact gas supplier.
NO
Replace the ignition
control or gas valve.
3. Is the gas
supply/nozzle
pressure okay?
4. Is the current
between the
connector and
the ionisation at
least 0.9µA DC.
YES
Go to step 2.
NO
Is the flame sensor
placed in the flame / is
the sensor's electrical
connection okay?
1. Is there a
short-lived
flame at
the ignition
attempt?
2. Is an ignition
spark present?
YES
Adjust / clean
the electrode /
connections.
NO
Replace the
ignition control.
YES
Go to step 3.
NO
NO
YES
Adjust / clean
/ replace the
electrode.
NO
Go to step 3.
Is the ignition electrode
placed correctly / is the
connection okay?
YES
Replace the sensor.
NO
Adjust the sensor.
Is there continuity in the
harness?