46
Installation manual
9.4 Table of pressure and adjustment
Liquied petro-
leum gases
Gas category Inlet pressure
(mbar)
Injector pres-
sure (mbar)
Injector size (⌀
mm)
Air reducing
plate (mm)
Label number May be avail-
able in follow-
ing countries
Butane mixture
/
Propane
mixture
3+ 28-30 /
37
No regulation 1.80 No 490375663 BE, CH, CY,
CZ, ES, FR,
GB, GR, IE, IT,
LT, LU, LV, PT,
SK, SI
Butane 3B/P 30, 37, 50 28 1.80 No 490375664 BE, CY, DK,
EE, FI, FR, GB,
HU, IT, LT, NL,
NO, SE, SI, SK,
RO, HR, TR,
BG, IS, LU, MT,
PL, AT, CH, DE,
SK
Propane 3P 30, 37, 50 28 1.90 No 490375665 FI, NL, RO, BE,
CH, CZ, IE, IT,
ES, FR, GR,
GB, HR, LT, NL,
PL, PT, SI, SK,
AT, CH, DE,
NL, LU, SK
Natural gas Gas category Inlet pressure
(mbar)
Injector pres-
sure (mbar)
Injector size (⌀
mm)
Air reducing
plate (mm)
Label number May be avail-
able in follow-
ing countries
2H, 2E 20 8 3.30 No Default AT, BG, CZ,
DK, EE, FI, GR,
HR, HU, IS, IE,
IT, LV, LT, NO,
PT, RO, SK, SI,
ES, SE, CH,
TR, GB, DE,
PL, LU
2E+ 20 / 25 No regulation 2.60 No 490375661 BE, FR
2E (G20) 20 8 3.30 No 490375662 NL
2L (G25) 25 12
2(43.46-45.3
MJ/m3 (0 °C))
(G25.3)
25 12
2LL 20 12 3.30 No 490375662 DE
When a machine shall be installed or used on high altitude (2001 feet and higher) a kit for high altitude must be
installed.
For kit No. please refer to the spare parts list.