9.5 Test run
• Loosen the measuring branch screw (2) 1/4 turn; connect a manometer to the measuring branch.
• Select a program with heat.
• Start the machine.
• Check the nozzle pressure, see “Table of pressure and adjustment”.
• If necessary adjust the regulator setting screw (4) behind the cover screw (3). Replace the cover screw (3) if
removed.
• Check that the gas is burning evenly. The blue flame on the burner is preferred.
• Tighten the screw (2) when the adjustments are done.
2
3, 4
fig.7120
9.6 Converting instructions
• Disconnect the power to the machine.
• Demount the back panel.
• Demount the air restriction plate (1).
• Demount the nozzle (2) and mount the new supplied nozzle.
• Re-mount the air restriction plate.
1
2
fig.X01102