17
Program
Start
1. Switch the user module to programming mode (See section 3).
2. Move to Area B (See “To Access Area B” in group 2 ).
3. Step forward using to 7_ _
4. Press Enter to enter subgroups within main groups 7 01
5. Step forward from 7 01 using to 7 04 and then press Enter
Note! The factory setting is displayed.
6. Press Enter
Note! The factory setting flashes and is changeable.
7. Step forward using till the setting is reached.
8. Accept the setting using All values are stored when the display stops
flashing.
Whentheprogramminghasbeencompleted,movetheswitchbacktonormalposition.
Or if further changes are to be carried out
9. Press Return to Subgroup 7 04.
10. Press Return to Main group 7 _ _.
11. Press Up or Down depending on the Main group number in
which changes are to be carried out.
Changing factory settings
In order to clarify things a step by step instruction of how to move within a main group fol-
lows.
Based on an example the instruction shows how to change the residual moisture factory
setting in program 4 (See Overview of factory setting Group 7).-
P
487 22 93 40.00
P
487 22 93 40.00