Troubleshooting
E 04 - The output sensor has short circuited
Error description
The error code indicates either that there is a short circuit in the NTC sensor connected to
the circuit board, or in the wires from the circuit board to the NTC sensor.
The error may also be caused by a defective circuit board.
The dryer stops operating.
Error analysis
0
10
20
30
40
50
60
70
80
90
100
0
C
1 2 3 4 5 T1 (V)
T2 T1 GND
E – 04
2. Defective
NTC interface
on PCB?
Measure the resistance
of the NTC sensor and
harness between P18-5
and P18-6 on main circuit
board.
Is the resistance between
4 to 6 kΩ at 20°C (68°F)?
Replace NTC sensor
or harness.
Go to step 2.
NO
YES
YES
Replace the PCB.
1. Defective
NTC sensor or
harness?
Alternative
Measure the voltage between GND and T1