Setting Implementation
Emptying water tank - warning
message permanent off
When using an external drain for
the condensed water.
1. Turn the programme selector to any programme.
2. Press simultaneously the SENSITIVE (Sensitiv) (2) and
TIME (Zeitwahl) (5) buttons and hold down for approx. 5
seconds.
The current setting is on the display:
warning
icon and - warning message is
off
warning
icon and - warning message is
switched on
By default the warning message is switched on and
always displayed at the end of the drying cycle or dur-
ing the cycle if the water container is full.
Hints for test institutes
Parameters possible to check by the Test In-
stitutes:
Energy consumption (corrected with final
humidity) during the cupboard dry cotton
cycle with nominal load.
Energy consumption (corrected with final
humidity) during the cupboard dry cotton
cycle with half load.
Final humidity (during cupboard dry cot-
ton, iron dry cotton and cupboard dry easy
care)
Condensation efficiency (corrected with fi-
nal humidity) during cupboard dry cotton
cycle with nominal and half load
All the cycles have to be checked in accord-
ance with EN 61121 (Tumble dryers for
household use – Methods for measuring the
performance).
Installation
Appliance positioning
It is recommended that, for your conven-
ience, the machine is positioned close to
your washing machine.
The tumble dryer must be installed in a
clean place, where dirt does not build up.
Air must be able to circulate freely all round
the appliance. Do not obstruct the front
ventilation grille or the air intake grilles at
the back of the machine.
To keep vibration and noise to a minimum
when the dryer is in use, it should be
placed on a firm, level surface.
Once in its permanent operating position,
check that the dryer is absolutely level with
the aid of a spirit level. If it is not, raise or
lower the feet until it is.
The feet must never be removed. Do not
restrict the floor clearance through deep-
pile carpets, strips of wood or similar. This
might cause heat built-up which would in-
terfere with the operation of the appliance.
Important!
The hot air emitted by the tumble dryer can
reach temperatures of up to 60°C. The ap-
pliance must therefore not be installed on
floors which are not resistant to high temper-
atures.
When operating the tumble dryer, the room
temperature must not be lower than +5°C
and higher than +35°C, as it may affect the
performance of the appliance.
Important! Should the appliance be moved,
it must be transported vertically.
Important! The appliance must not be
installed behind the lockable door, a sliding
door a door with a hinge on the opposite side
to that of the appliance.
Removing transport safety packaging
Caution!
Before use all parts of the transport packag-
ing must be removed.
1. Open loading door
18 electrolux