52
Cleaning Cycle:
Buzz during cleaning
Pump buzzing - Check for restricted water ow to machine
Replace the non-return valve after coee cleaning valve
Cleaning tablet not dissolved
Blocked cleaning non-return valve
Coee Cleaning valve: Clogged, not getting power, or coil not working
Requests another Cleaning immediately after Cleaning cycle complete
Low water pressure, pressure dropped during cleaning
Water switch not reading, bend bracket down to ensure activation
Grounds drawer switches not closing
Asks to re-start Cleaning before Cleaning cycle complete
Low water pressure, pressure dropped during cleaning
Water switch not reading, bend bracket down to ensure activation
Grounds drawer switches not closing
Stuck on the cleaning progress bar
Switch ON OFF does not clear
Water is shut o during cleaning
Another fault appears during cleaning
After exiting standby mode
Turn o the cleaning commands to cancel cleaning cycle and restart cleaning:
- switch o the machine
- move DIP switch #6 to ON
- restart the machine
- restart cleaning
- return to the main menu
Restore normal operation:
- switch o the machine
- return the DIP switch to normal position (all switches OFF)
- switch on the machine
Troubleshooting