ALARM CODES
SSD-P APdV, EB, HD 01/05 8.7 599 34 71-47
Are pressure switch hoses and the air
trap system free (you can disconnect
the hoses and blow in them to check
if the system is free) -see pic. 08,a,b-
YES
The analogic pressure switch is giving an error during the calibration phase
(At the beginning of each cycle the appliance drain to empty the tub
and create a 0 level to verify the calibration of the analogic pressure switch)
Checks to do:
E32
NO
Clean/change the hoses and/or air trap
system and repeat completely the
diagnostic cycle to verify any further
possible fault
Select a washing cycle. After few
minutes did the machine fill with water
and the motor is turning?
Check the draining system (filter,
drain pump, drain hose). Is the
machine draining correctly?
Clean the draining system.
Machine is OK
NO
Change the Analogic pressure switch
and run again the diagnostic cycle for
any further alarm code
YESYES
YES
NO