24
ADDR: 000 ZONE 01
VAL=> 58 08 12 05
First digit blinking
Group ID
Parameter address
After entering parameter changes
Upon entering a digit, the display automatically moves to the next digit. To move to the next digit without
entering a modification, press MENU/NEXT. To move back to the previous digit, press Q.
Entering Hex data
Pressing # scrolls through the hexadecimal digits A, B, C, D, E and F. If the original digit is decimal (0-9),
press # to change the digit to A. If the original digit is hexadecimal (A-F), press # to move to the next
hexadecimal digit in sequence.
4.4: Programming Parameters
This section comprises a complete listing of the Summit 3208GLD control panel’s programming parameters.
The following table lists the addresses for each group of programming parameters.
ADDRESSES PARAMETERS ADDRESSES PARAMETERS
000-127
Zone Parameters
388
Swinger Parameters
128-131
System Parameters
389-409
Opening & Closing Windows
132-139
Keypad Parameters
410
Bell Cut-Off
140-179
Telephone Numbers
411
Dealer Lockout & Latchkey
180-195
Account Numbers
412-475
Custom LCD Zone Descriptors
196-197
Telephone Line Parameters
476
Zone Expanders
198-201
Communication Protocols
477-490
Relay Parameters
202-261
Zone Oriented Event Codes
491-493
Periodic Test
262-295
Event Oriented Event Codes
494
Arming Options & Arming Ring
296-310
Event & Message Routing
495
Detailed Display, Bell Muting
& Fire Sensor Reset
378-381
Exit Timers
496
Police Key Operation
& RP Communication Options
382-384
Entry Timers
497-498
AC Loss & Restore
385-387
Pulse Counters
499
Listen-In Time Out

Related product manuals