HEATING
TEMP CORRECT
CONTROL bY GSM
TO SENdER
TO ANOTHER NR
420000000000---
11
10
Setting of the thermostat functions.
HEATING =
if the current temperature value falls below the desired
one, the output relay (for heating systems) switches on.
COOLING = if the current temperature value exceeds the desired
one, the output relay (for cooling systems) switches on.
HEATING / COOLING
(factory setting of HEATING)
Choose HEAT/ COOL by turning the“ “ and confi rm “ “.
11
Used to correct temperature measured by the thermostat. Setting
must earliest be done after 12-hour operation when the internal sen-
sor temperature has settled. Measure the room temperature with a
thermometer. If it differs from the thermostat temperature, set corre-
ction within the range from -5°C to +5°C.
TEMPERATURE CORRECTION
Set the correction by turning the“ “ button, and confi rm with
the “ “ button.
(factory setting of 0 °C)
12
This constant selects the possibility of thermostat control via
a GSM module.
NE GSM module disabled
ANO GSM module enabled. Set CONST tEL nO and CONST13!
USE GSM
Choose YES/NO by turning the “ “ and confi rm“ “.
(factory setting of NO)
Note: If you choose YES and do not connect a module, the “GSM UNCONNECTED” notice appears on the LCD
basic screen. The GSM module control is described in detail in the GST1(2) instructions.
tEL nO
This constant can be set if CONST12 = YES. It specifi es the
possibility of connecting a GSM module for control by means of
a mobile phone.
Allows the following options:
PHONE NUMBER SETTING
1) TO SENdER = SMS will be sent back to
the telephone number from which the
message was sent.
2) TO ANOTHER NR = SMS will be sent back to
the telephone number entered in
the thermostat.
3) bOTH NUMbERS = SMS will be sent back to both
telephone numbers (combination options
1 and 2).
When choosing 2) and 3) option we enter a phone number
n the international format (420123456789), to which return
SMS messages on the thermostat condition should be sent.
Is possible to enter a phone number min. 10-digit to 15-digit.
Turning the “ “ button, enter the phone number stepwise; confi rm each setting with the
“ “ button.
For automatically receiving SMS about exceeding the limits (CONST2 and CONST3) is requi-
red to enter the phone number into the thermostat option 2) or 3).