5.0 Maintenance (continued)
Maintenance
Daily or before compressor starting
Remove dirt and dust from compressor.
Check oil level in crankcase, replenish if needed.
Check Belt tension.
Drain condensate from air receiver.
150 hours or 10 days
Drain condensate from receiver.
Drain oil from compressor after running to warm oil, add new oil to compressor.
250 hours or 20 days
Check for unusual noise or vibration.
Check bolts for tightness.
Check for air leaks in piping, cooler, safety valves and drain valves.
Check pressure switch operation and settings.
Remove inlet air filter and clean with compressed air, reassemble on compressor.
Frequency Maintenance Required
1000 Hours or 3 Months
a) Inspect valves
b) Check piping for leaks
c) Inspect check valve
d) Change inlet filter element
e) Change breather valve
f) Check pressure setting
g) Check bolts for tightness
2500 Hours or 1 Year
a) Annual preventative maintenance kit with tune up kit
Clean coolers
a) Clean and test air receiver for leaks
2 Years
b) Change safety valves
7500 hours or 3 Years a) Overhaul Compressor